<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Physiology and Pharmacology</title>
<title_fa></title_fa>
<short_title>Physiol Pharmacol</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ppj.phypha.ir</web_url>
<journal_hbi_system_id>32</journal_hbi_system_id>
<journal_hbi_system_user>journal32</journal_hbi_system_user>
<journal_id_issn>24765236</journal_id_issn>
<journal_id_issn_online>24765244</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/phypha</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>(previous ISSN: 17350581)</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1388</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2009</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>اندازه گیری اتوماتیک تغییرات لحظه ای دیواره شریان کاروتید با استفاده از تصاویرمتوالی فراصوتی</title_fa>
	<title>Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images</title>
	<subject_fa>Cardiovascular Physiology/Pharmacology</subject_fa>
	<subject>Cardiovascular Physiology/Pharmacology </subject>
	<content_type_fa>Experimental research article</content_type_fa>
	<content_type>Experimental research article</content_type>
	<abstract_fa>چکیده – در این مطالعه یک روش آنالیز کامپیوتری با استفاده از برنامه گرادیان بیشینه برای استخراج تغییرات لحظه ای دیواره دور و نزدیک شریان کاروتید مشترک با استفاده از تصاویر متوالی فراصوتی ارائه شده است. در این کاربری خاص؛ برنامه گرادیان بیشینه اصلاح شده و چند مشخصه از الگوریتم برنامه ریزی پویا به آن اضافه شده است. برنامه روی شریان کاروتید مشترک 15 داوطلب سالم مورد ارزیابی قرار گرفت. اندازه موضعی شدت روشنایی رگ؛ گرادیان شدت روشنایی و شرایط مرزی از تمام تصاویر فراصوتی متوالی و در طول سه سیکل قلبی استخراج شد. در این مطالعه تغییرات لحظه ای دیواره های دور و نزدیک و نیز قطر لومن شریان برآورد شد. برای اعتبارسنجی روش اتوماتیک؛ اندازه گیری های دستی انجام گرفت و با روش اتوماتیک مقایسه شد. سپس قطر در حداکثر سیستول؛ در انتهای دیاستول و نیز قطر میانگین در طول سه دوره قلبی با استفاده از روش اتوماتیک استخراج شد و با اندازه گیری های حاصله به روش دستی مقایسه شد. با استفاده از آنالیز توصیفی pair t-test تمایز معنی داری میان دو روش اتوماتیک و دستی مشاهده نشد (عدد p بیش تر از 05/0). همبستگی معنی داری میان پارامترهای اندازه گیری شده با روش اتوماتیک و روش دستی با انالیز همبستگی (ضریب برازش 85/0 با عدد p کمتر از 05/0) و با تورش ناچیز (003/0 میلی متر) نیز توسط آنالیز Blant-Altman تعیین شد. نتایج این مطالعه نشان می دهد که روش آنالیز کامپیوتری قادر است به طور اتوماتیک تغییرات لحظه ای دیواره شریان را در تصاویر فراصوتی متوالی استخراج کند..</abstract_fa>
	<abstract>Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far
and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient
algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming
algorithm for our applications.
Methods: The algorithm was evaluated on the common carotid artery of 10 healthy volunteers. Local measurements
of vessel intensity, intensity gradient and boundary continuity are extracted for all of the sequential ultrasonic frames
throughout three cycles. We extracted the instantaneous changes of far and near arterial walls and hence the lumen
diameter. The manual measurements were applied and compared for validation of the automatic method. Peak systolic,
end diastolic and mean diameters extracted by the automated method were compared with the same parameters
measured by the manual method throughout three cycles.
Results: There was no significant difference between automated and manual methods (p&gt;0.05) with paired t-test
analysis. In the verification study, correlation between automated and manual methods was excellent (R2 = 0.85,
p&lt;0.05) with a negligible bias (0.003 mm) as determined by Bland Altman analysis.
Conclusion: It is concluded that computerized analyzing method can automatically detect the instantaneous changes
of the arterial walls in sequential B-mode images.
</abstract>
	<keyword_fa>اولتراسوند، رفتار بیومکانیکی شریان کاروتید، الگوریتم ماکزیمم گرادیان</keyword_fa>
	<keyword>Ultrasound, Biomechanical behavior, Carotid artery, Maximum gradient algorithm</keyword>
	<start_page>308</start_page>
	<end_page>318</end_page>
	<web_url>http://ppj.phypha.ir/browse.php?a_code=A-10-53-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mehravar</first_name>
	<middle_name></middle_name>
	<last_name>Rafati</last_name>
	<suffix></suffix>
	<first_name_fa>مهرآور</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رفعتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>320031947532846006597</code>
	<orcid>320031947532846006597</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Manijhe</first_name>
	<middle_name></middle_name>
	<last_name>Mokhtari-Dizaji</last_name>
	<suffix></suffix>
	<first_name_fa>منیژه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مختاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Mokhtarm@modares.ac.ir</email>
	<code>320031947532846006598</code>
	<orcid>320031947532846006598</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Hajir</first_name>
	<middle_name></middle_name>
	<last_name>Saberi</last_name>
	<suffix></suffix>
	<first_name_fa>هژیر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صابری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>320031947532846006599</code>
	<orcid>320031947532846006599</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Hadi</first_name>
	<middle_name></middle_name>
	<last_name>Grailu</last_name>
	<suffix></suffix>
	<first_name_fa>هادی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گرایلو</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>320031947532846006600</code>
	<orcid>320031947532846006600</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
