نقش مسیر آهسته بعد از سوزاندن مسیر سریع گره دهلیزی بطنی در خواص پایه و وابسته به سرعت گره دهلیزی بطنی جدا شده خرگوش
Role of slow pathway after nodal fast pathway ablation on the basic and rate- dependent properties of the isolated rabbit atrioventricularNode
Cardiovascular Physiology/Pharmacology
Cardiovascular Physiology/Pharmacology
Experimental research article
Experimental research article
<p align="right"> <strong> مقدمه </strong><strong>: </strong>هدف از این مطالعه کسب دید تازهای در ارتباط احتمالی بین خواص کارکردی مسیر آهسته پنهان و خواص وابسته به سرعت گره دهلیزی بطنی است. </p><p align="right"> <strong> روش </strong><strong>ها : </strong>در یک گروه<strong> </strong>شامل 7 نمونه از گره دهلیزی بطنی با تغذیه سطحی خرگوش پروتکل های تحریکی وابسته به سرعت ریکاوری ، تسهیل و خستگی اجرا شدند. سوزاندن با کمک ولتاژ مستقیم (110-100 ولت) توسط الکترود نقره تک قطبی انجام گرفت. </p><p align="right"> <strong> یافته ها </strong><strong>: </strong>سوزاندن مسیر سریع باعث کاهش معنی دار میزان تسهیل شد ولی روی زمان خستگی و تحریک ناپذیری گره ای تاثیر ی نداشت. مهمترین اثر سوزاندن مسیر سریع افزایش معنی دار زمان هدایت حداقل بود. </p><p align="right"> <strong> نتیجه </strong><strong>گیری : </strong>سوزاندن مسیر سریع سبب آشکار شدن اثرات مسیر آهسته پنهان می شود. خواص وابسته به سرعت گره دهلیزی-بطنی به تداخل دینامیک دو مسیر آهسته و آهسته پنهان بستگی دارند. مسیر سریع در ایجاد پدیده تسهیل موثر است. </p>
<p> <strong> Introduction </strong>: The aim of this study is to obtain new insight into possible relation between functional properties of slow concealed pathway and rate-dependent properties of AV-node. </p><p> <strong> Methods </strong>: Rate-dependent nodal properties of recovery, facilitation,<sup> </sup>and fatigue were characterized by stimulation protocols in one groups of (N=7) isolated superfused AV-Nodal rabbits. Small miniature lesions were made by delivering constant voltage (110 V-100 s) with unipolar silver electrode. </p><p> <strong> Results </strong><strong>: </strong>Fast pathway ablation significantly decreased facilitation and had no effect on fatigue and nodal refractoriness. The most important effect of fast pathway ablation was prolongation of minimum conduction time. </p><p> <strong> Conclusion </strong><strong>: </strong>The FP-ablation revealed the presence of the concealed SP. Rate-dependent property of node is dependent to dynamic interaction between concealed slow with slow pathway. Fast pathway involved in the mechanism of facilitation. </p><p> </p>
سوزاندن ، مسیر سریع ، گره دهلیزی – بطنی، آریتمی
ablation, AV node, Fast pathway, arrhythmia
28
36
http://ppj.phypha.ir/browse.php?a_code=A-10-245-2&slc_lang=en&sid=1
vahid
khori
vaph99@yahoo.com
320031947532846005438
320031947532846005438
Yes
Golestan Cardiovascular Research Center
mohsen
nayebpour
320031947532846005439
320031947532846005439
No
Department of Pharmacology
abbas
mirabbasi
320031947532846005440
320031947532846005440
No
Golestan Cardiovascular Research Center
mona
pourabouk
320031947532846005441
320031947532846005441
No
Golestan Cardiovascular Research Center